BJXNM - CAT 2; RC-0002-660000-B; CATALYST

  • MSDS: BJXNM
  • Manufacturer: PERMAGILE INDUSTRIES INC
  • Product Name: CAT 2; RC-0002-660000-B; CATALYST
  • National Stock Number: 5970-00-689-8832
Product Identification

Product ID:CAT 2; RC-0002-660000-B; CATALYST
MSDS Date:10/03/1990
FSC:5970
NIIN:00-689-8832
Kit Part:Y
MSDS Number: BJXNM

Responsible Party
PERMAGILE INDUSTRIES INC
101 COMMERCIAL STREET
PLAINVIEW, NY 11803
US

Emergency Phone: 516-349-1100

Info Phone: 800-645-7546

Preparer: LAWRENCE J.DEMAIO

Cage: 13549

Contractor
PERMAGILE INDUSTRIES INC
PLAINVIEW, NY 11803 US

Telephone: 516-349-1100/800-424-9300(CHEMTREC)

Cage: 13549

Ingredients

ORGANOTIN COMPOUND

OSHA PEL S, 0.1 MG/M3 (SN)

ACGIH TLV: S, 0.1 MG/M3 (SN)


PROPRIETARY COMPONENTS

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS 1470 MG/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF EYES,SKIN OR
RESPIRATORY TRACT;HARMFUL IF SWALLOWED.CHRONIC:NO DATA
AVAILABLE,IRRITATION OF EYES AND SKIN POSSIBLE.
Explanation of Carcinogenicity:DATA PER MSDS
Effects of Overexposure:INHALATION: VAPORS MAY IRRITATE RESPIRATORY
TRACT PROLONGED EXPOSURE MAY CAUSE HEADACHE, DIZZINESS, NAUSEA AND
VOMITING. INGESTION:MAY BE HARMFUL. EYES:CAUSES IRRITATION ON
CONTACT AND DAMAGE PERMANEN TLY. IF HEATED, VAPORS MAY CAUSE
TEARS/IRRITATION. SKIN: CONTACT MAY CAUSE SEVERE IRRITATION AND/OR
BURNS.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYES AND SKIN DISORDER
MAY BE AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR.GIVE ARTIFICIAL RESPIRATION
IF NEEDED. GET MEDICAL ADVICE. EYES:IMMEDIATELY FLUSH WITH PLENTY
OF WATER FOR 15 MINUTES. GET MEDICAL ADVICE. SKIN: REMOVE
CONTAMINATED CLO THING. WASH WITH SOAP AND WATER. IF IRRITATION
PERSISTS, GET MEDICAL ADVICE. INGESTION: GIVE NOTHING BY MOUTH IF
UNCONSCIOUS. GIVE LARGE AMOUNT OF MILK MIXED WITH SALT. GET
IMMEDIATE MEDICAL HELP.

Fire Fighting

Flash Point Method:PMCC
Flash Point:455F,235C
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED;FIRE OR EXCESSIVE HEAT MAY
CAUSE PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:USE PROPER PERSONAL PROTECTION;CONTAIN FREE
MATERIAL IF POSSIBLE;USE SUITABLE INERT ABSORBENT MATERIAL AND
RECOVER FOR PROPER DISPOSAL IN AN APPROVED CONTAINER.FOR LARGE
SPILL,DIKE AREA WITH SAND TO C ONTAIN SPILL.PREVENT FROM ENTERING
TO WATERWAYS.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
CONTAINERS FROM PHYSICAL DAMAGE.
Other Precautions:DO NOT TAKE INTERNALLY. DO NOT BREATHE MIST. AVOID
PROLONG OR REPEATED BREATHING OF VAPOR. AVOID CONTACT WITH EYES.
USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR METALLIC
FUMES AS REQUIRED IF ABOVE PEL/TLV.
Ventilation:LOCAL/GENERAL TO MAINTAIN PEL/TLV.
Protective Gloves:NEOPRENE, NITRILE, OR NATURAL RUBBER
Eye Protection:SAFETY GOGGLES WITH SIDE SHIELD
Other Protective Equipment:EYE WASH STATION,WORK CLOTHING AND APRON AS
REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
ITEM IS TWO PARTS PRODUCT. THIS ENTRY DESCRIBES CATALYST, PART B. PART
A IS UNDER PNI 'A' THIS NSN.

Chemical Properties

HCC:N1
Spec Gravity:1.05
Evaporation Rate & Reference:<1.0 (N-BUTYL ACETATE =1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW LIQUID,FATTY ACID ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED
Stability Condition to Avoid:HIGH TEMPERATURES(100C OR ABOVE)
Hazardous Decomposition Products:METALLIC FUMES AND OXIDES OF CARBON
Conditions to Avoid Polymerization:CONTACT WITH EPOXY COMPOUND.

Disposal

Waste Disposal Methods:CONSULT LOCAL AUTHORITIES.DISPOSAL MUST BE MADE
IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.